Secure Checkout
LX-200 Hand Held Lux Meter Measure Illuminance in Foot Candles or LUX with Datalogging

Thumbnail Filmstrip of LX-200 Hand Held Lux Meter Measure Illuminance in Foot Candles or LUX with Datalogging Images

    LX-200 Hand Held Lux Meter Measure Illuminance in Foot Candles or LUX with Datalogging

    Overview

    The LX 200 handheld luxmeter is designed to measure illuminance in foot candles or lux. Features include Instantaneous measurement, display illuminance for local measurements, timed measurement of illuminance min/max values display and Illuminance averaged value calculation.
    Features
    • Measuring range: from 0.1 to 200,000lux (from 0,01 to 18,585 fc)
    • Sensing element in silicon photodiode (spectral responsivity in accordance with photonic curve CIE)
    • Displaying of instantaneous, maximum and minimum values
    • Evolution of illuminance according to weather conditions
    • Relative measurement to a reference point
    • Includes LLX200 software Operating software for data processing and printing of reports
    Price Starting At:
    $949.00
    Need help? Contact us with questions.

      Shipping Estimated Shipping 6 to 8 weeks.
    LX-200 Lux Meter Specifications
    Measuring Range From 0.1 to 200,000 Lux
    From 0.00 to 18,585 fc
    Measuring Units kfc, fc, lux, klx
    Directional Sensitivity (f2)1 < 6%
    Linearity (f3)1 < 2%
    Measurement Capability* From 04h30 to 99 days
    Display Backlit LCD graphic 128 x 64mm
    Operating Temperature 32 to +122°F (0°C to +50°C) In non-condensation condition.
    Storage Temperature 32 to 122°F (0°C to +50°C)
    Housing Dimensions without Sensor 4.75 x 2.9 x 1.3 inches (120 x 58 x 34 mm)
    Mini-USB plug For USB power supply adapter and data transfer
    Power Supply 3 AAA batteries
    Battery Life 72 hours minimum, continuous operation
    European Directives 2004/108/EC EMC; 2006/95/EC Low voltage;
    2011/65/EU RoHS II; 2012/19/EU WEEE
    Note 1: The f2 and f3 coefficient are defined according to the French NF C 42-710 standard. * According to the mode (uniformity, temporal or cartography)
    LX-200 Lux Meter Illuminance Measure Range 0.0 to 200,000 Lux
    Accuracy ±2% of reading or ±2 lux
    Display Unit Resolution
    0.0 to 10.0 lx 0.1
    10.0 to 99.9 lx 0.1
    100.0 to 999.9 lx 0.1
    1000 to 9999 lx 1
    10.00 to 99.99 klx 0.01
    100.00 to 200.00 klx 0.1
    Illuminance Measure Range 0.0 to 18585 fc
    ±2% of reading or ±0.19 fc
    Display Unit Resolution
    0.00 to 1.00 fc 0.01
    1.00 to 99.99 fc 0.01
    100.0 to 999.9 fc 0.1
    1000 to 9999 fc 1
    10.00 to 18.58 kfc 0.01
    * All the accuracies indicated in this technical datasheet were stated in laboratory conditions, and can be guaranteed for measurements carried out in the same conditions, or carried out with calibration compensation.