    The LX 100 handheld luxmeter is designed to measure illuminance in foot candles or lux. Features include Instantaneous measurement, display illuminance for local measurements, timed measurement of illuminance min/max values display and Illuminance averaged value calculation.
    Features
    • Measuring range: from 0.1 to 150,000 lux (from 0,01 to 13940 fc)
    • Sensing element in silicon photodiode (spectral responsivity in accordance with photonic curve CIE)
    • Pause function to eliminate any unrepresentative illuminance
    • Timed measurement: min., max. and average values
    • Relative measurement to a reference point
      Shipping Estimated Shipping 6 to 8 weeks.

    LX-100 Lux Meter Specifications
    Measuring Range From 0.0 to 150,000 Lux
    From 0.00 to 13,940 fc
    Measuring Units kfc, fc, lux, klx
    Directional Sensitivity (f2)1 < 6%
    Linearity (f3)1 < 3%
    Measurement Capability 3 days - 03D00H00M
    Display Backlit LCD graphic 128 x 64mm
    Operating Temperature 32 to +122°F (0°C to +50°C) In non-condensation condition.
    Storage Temperature 32 to 122°F (0°C to +50°C)
    Housing Dimensions 4.75 x 2.9 x 1.3 inches (120 x 58 x 34 mm)
    Mini-USB plug For USB power supply adaptor
    Power Supply 3 AAA batteries
    Battery Life 72 hours min, continuous operation
    European Directives 2004/108/EC EMC; 2006/95/EC Low voltage;
    2011/65/EU RoHS II; 2012/19/EU WEEE
    Note 1: The f2 and f3 coefficient are defined according to the French NF C 42-710 standard.
    LX-100 Lux Meter Illuminance Measure Range 0.0 to 150,000 Lux
    Display Unit Resolution Accuracy
    0.0 to 10.0 lx 0.1
    10.0 to 99.9 lx 0.1
    100.0 to 999.9 lx 0.1 ±3% of reading or ±3 lux
    1000 to 9999 lx 1
    10.00 to 99.99 klx 0.01
    100.00 to 150.00 klx 0.1
    LX-100 Lux Meter Illuminance Measure Range 0.0 to 13,940 fc
    Display Unit Resolution Accuracy
    0.00 to 1.00 fc 0.01
    1.00 to 99.99 fc 0.01
    100.0 to 999.9 fc 0.1 ±3% of readin
    or ±0.28 fc
    1000 to 9999 fc 1
    10.00 to 13.94 kfc 0.01
    Eack LX-100 is suplied with LX100 housing with silicon photodiode sensor and glass filter correction, battries, calibration certificate, soft case and quick reference guide.