High accuracy dual channel temperature,
process signal and pressure hand held Documenting Process ALL IN
ONE Calibrator
NOW AVAILABILE THE MICROCAL 20 DPC IS INTRINSICALLY SAFE MODELS
Intrinsically Safe
for zone 0 with ATEX certification, class II 1G EEx ia IIC T4 (-20°C TAmb + 50°C) X.
|
 |
|
The MicroCal DPC 20 Series Multifunction Temperature, Process Signal,
Pressure all-in-one calibrator is designed to help in maintaining your Quality System (ISO 14000, ISO 9001, ISO 17025), the highly accurate (up to 0.006% rdg)
the MicroCal DPC 20 calibrator will simultaneously measure and simulate mA, DC voltage, 14 different thermocouples, 10
RTD's types, pressure, resistance, frequency, and pulse signals.
Features:
• Large Graphic Back-Lit Display • Easy to Use One Hand Operation • Patent
pending Push and Lock Thermocouple, and Banana Plug Connection • Dual Channel High Accuracy Thermometer • 4-Wire Resistance Thermometer • mA, mV, V, frequency, pulse •
All IEC, DIN and JIS Thermocouples and Pt, Ni, and
Cu RTD's • Simultaneous Measurement and
Simulation for Transmitter Calibration • Real-Time
Clock with memory for in-field calibration procedures ("as found" and "as left" data points) • RS232 for instrumentation management with CalpMan Software • Optional Internal Pressure Sensors (PLUS
and XP Models) • Optional External
Pressure Modules • Optional HART
Communications
|

|
Dual input channels Allows you to simultaneously read and source different parameters which
is ideal for calibrating temperature transmitters. Both channels (CH1 and CH2) on the model MicroCal 20 XP can be set for
simultaneous input. You can use the MicroCal 20 DPC calibrator as a two channel high accuracy thermometer for 14 Thermocouples
types and 10 types of RTD's certification.
4-wire resistance thermometer Resistance and temperature with resistance thermometer may be measured on a 2, 3, and 4 wire connections for
best accuracy and resolution (0.01°F). This process calibrator is compatible with pulsed transmitters.
Rj compensation The
MicroCal 20 DPC process calibrator has accurate and fast response compensation through a special low thermal capacity design
of binding posts, which incorporates a thin film high accuracy Pt100 as cold junction reference. The internal reference allows
the maximum accuracy for the 15 to +130°F temperature range. A remote Pt100 sensor can be connected for special application
(from 15 to +212°F). It is possible to set manually the compensation temperature (from -60 to +212°F) by keyboard.
Frequency - Counts The MicroCal 20 DPC process calibrator's
simulation mode is designed to generate a zero-based square pulse, with an adjustable amplitude, at a frequency up to 20 KHz.
A preset number of pulses may be programmed and transmitted to test or calibrate totalizers and counters. This calibrator
can be configured to measure frequency and count pulse (totalizer mode). Technical units in Hz, pulse/h, and pulse/m. The
threshold is adjustable from 0 to 20 V with 0.01 V resolution.
Internal pressure sensors Optional one or two built-in pressure sensors are available for the MicroCal 20 DPC Plus and
XP models pressure calibrator to cover main pressure application including gauge, differential, absolute, and vacuum. The
calibration matrix pressure/temperature is stored in internal non-volatile memory.
|
MicroCal 20 DPC Plus/XP Internal Pressure Modules
|
Ordering Code | INTERNAL
SENSORS AISI316SS MicroCal 20 DPC Plus/XP only | Resolution | 0 | No internal pressure sensor. External only | 2 | -100
to 100 mbar (gauge) | 0.001mbar | 3 | -500 to 500 mbar (gauge) | 0.01mbar | 4 | -0,95 to 1bar (gauge) | 0.01mbar | 5 | -0,95
to 2bar (gauge) | 0.01mbar | 5A | 2bar (absolute) | 0.01mbar | 6 | -0,95
to 7bar (gauge) | 0.1mbar | 7 | -0,95 to 20 bar (gauge) | 0.1mbar | 7A | 20bar (absolute) | 0.1mbar | 9 | 200bar
(absolute) | 0.1mbar |
|
|
External pressure modules Each MicroCal 20 DPC is equipped with a connector for optional external pressure "smart" modules. A wide selection of
modules are available as accessories for ranges up to 10,150 psi. The calibration matrix pressure/temperature is stored in
internal non volatile memory.
|
MicroCal 20 DPC External Pressure Modules
|
GAUGE EXTERNAL PRESSURE MODULES | Model
Number | Range | Resolution | BB480009 | -100 to 100
mbar (1.5 PSI) | 0.001mbar | BB480010
| -500 to 500 mbar (7 PSI) | 0.01mbar | BB480011 | -0.95 to 1
bar (15 PSI) | 0.01mbar | BB480012 | -0.95 to 2 bar (30 PSI) | 0.01mbar | BB480013 | -0.95 to 7bar
(100 PSI) | 0.1mbar | BB480014 | -0.95 to 20 bar (300 PSI) | 0.1mbar | BB480015 | -0.95 to 35
bar (500 PSI) | 1mbar | BB480016 | 0 to 70 bar (1000 PSI) | 1mbar | BB480017 | 0 to 150 bar
(2000 PSI) | 1mbar | BB480018 | 0 to 350 bar (5000 PSI) | 10mbar | BB480019 | 0 to 700 bar
(10000 PSI) | 10mbar | ABSOLUTE - EXTERNAL PRESSURE MODULES | Model
Number | Range | Resolution | BB480020 | 0 to 2 bar
(30 PSI) | 0.01mbar | BB480021
| 0 to 20 bar (300 PSI) | 0.1mbar |
|
|
|
| MicroCal 20 DPC IS Plus |

|
| All in One Multifunction Calibrator Shown |
|
|
|
 |
|
|
 |
|
|
 |
|
|
|
Multifunction Temperature and Process Calibrators, Thermocouple and mA Calibrators, Thermocouple and RTD Dry Block Calibrators, Portable Infrared Thermometers, Fixed Mounted Industrial Infrared Thermometers, Thermocouple and RTD 2-wire Head Mounted Transmitters, DIN Rail Mounted Thermocouple and RTD Transmitters, Temperature and Process Panel Meters, Temperature & Humidity Transmitters, Hand Held Digital Thermocouple Thermometers, MIST Microprocessor Based Integral Transmitter RTD Temperature
Sensors, Industial Test tools and Maintenacnce Kit, Indoor Air Qualitity (IAQ) and Test Meters, Hand Held Humidity and Air Flow Meters, Industrial MicroTool Portable Gas Leak Detection Meters, Pressure Measurement and Calibration Instruments
Temperature & Process Instruments Inc. * 1767 Central Park Avenue * Suite 112 * Yonkers
* NY * 10710 Phone: 1-914-673-0333 Fax: 1-866-292-1456 Email: sales@tnp-instruments.com© 2006 - 2009 Temperature & Process Instruments, Inc.
|
|
|
 |