New MC-1210 High Accuracy
Dual Display Multifunction Temperature and Process
Calibrator
with NIST
Calibration Certificate
Special Price $2089.00 save 5%
Precision Dual Display Multifunction Calibrator
|
|
New MC-1210 Multifunction Temperature and Process Calibrator |

|
| Supplied with Protective Rubber Boot,
Test Leads and NIST Certificate |
Prices Start at $2199.00
Special Price
$2089.00
save 5%

MC-1210 New ClearBrite™
Display Large Easy to Read |

|
|
Introducing the NEW MC-1210 multifunction temperature and process calibrator. It’s a rugged and reliable universal calibrator with the new ClearBrite High Graphic dual display and isolated read back The MC-1210 can power a
transmitter under test while reading its milliamp output. Truly an all-in-one calibrator. The MC-1210 calibrator provides the functions and accuracy associated with fixed-installation, laboratory instrument, and has everything needed for virtually any calibration task. Measure and source
thermocouples, RTDs, current, voltage, and frequency, and source pulse trains.
A communications port compatible with both Fluke® 700 Series and
Beta Calibrators pressure modules is provided, as is an isolated mA/V read-back circuit. Arrow keys, direct numeric keypad entry, and three software driven
function buttons, plus a large backlit, menu-driven graphics display combine to provide a highly intuitive, simple yet powerful
operator interface.
With a built-in 250 Ohm resistor for HART® compatibility, the MC-1210 is compatibility with smart transmitters and PLCs, full fuse-less protection, are just some of the additional features that make the MC-1210 the single most
indispensable tool available for virtually any calibration task.
Features
• New ClearBrite™ High Graphic Display
• 3 Key Martel Menu System
• Measure and source Thermocouples (13 types), RTDs (13 types), Ohms, current, voltage, frequency and source pulse trains signals
• Isolated mA/V read-back circuit for complete transmitter calibration
• Built-in 250 Ohm resistor for HART® compatibility
• Communication port compatible with both Fluke 700 Series and Beta Calibrator pressure modules
• Built-in 24V supply can drive 4 to 20mA loops up to 1000 Ohms
• All source modes can be programmed with dedicated set-points to speed calibration and linearity tests
• Highest accuracy in class to 0.015% of reading
• Meets CE requirements and is designed to IEC 1000 safety standards
|
Specifications
Environmental
Operating Temperature: -10°C to +50°C
(-14°F to 122°F)
Storage Temperature: -20°C to +70°C
(-4°F to 158°F)
Stability:
±0.005% of reading/°C outside of 23 °C ± 5°C
Power Requirements:
6Vdc; Batteries 4 AA alkaline (supplied) or optional rechargeable
Mechanical Dimensions:
8.5" H x 4.8" W x 2.1"
D
(22 x 12 x 5.3
cm)
Weight:
1.8 lbs (0.82
kg)
Signal Specifications
Voltage
Read and Source
Source:
0.000 to 20.000Vdc Read: Isolated 0.000 to 30.000Vdc
Non-Isolated 0.000 to 20.000Vdc
|
Thermocouple
Types and Ranges:
See
table below Accuracy:
See Table Below
Temperature scale:
ITS90
mV
Read/Source: -10.000 to +75.000 mV
Current (mA)
Source:0.000 to 24.000mA
Read Isolated:
0.000 to 24.000mA
Non-Isolated: 0.000 to 24.000mA
Frequency (1 to 20 V selectable amplitude)
CPM Source and Read:2.0 to 600.0 CPM Hz Source and Read: 1.0 to 1000.0 Hz
kHz Source and Read: 1.0 to
10.00 kHz
Pulse (Source only; 1 to 20 V selectable amplitude)
Pulses: 1 to 30,000.0 - 2
CPM to 10 kHz
Ohms
Source:
5.0 to 4000 Ohms
Read: 0.00 to 4000.0 Ohms
|
Thermocouple Range and Accuracy
| TC Type | Range °C (°F) | Accuracy* | | | -210.0 to 0.0°C (-346 to
32°F) | 0.4°C
(0.7°F) |
|
J | 0 to
800.0°C (32 to 1472°F) | 0.2°C (0.4°F) |
|
| 800.0 to 1200.0°C (1472 to 2192°F) | 0.3°C (0.5°F) |
|
| -200.0 to 0.0°C (-328 to 32°F) | 0.6°C (1.1°F) |
|
K | 0 to 1000°C (32 to 1832°F) | 0.3°C (0.5°F) |
|
| 1000.0 to 1372.0°C (1832 to 2502°F) | 0.5°C (0.9°F) |
|
T | -250.0 to 0.0°C (-418 to 32°F) | 0.6°C (1.1°F) |
|
| 0 to 400.0°C (32 to 752°F) | 0.2°C (0.4°F) |
|
E | -250.0 to -100.0°C (-418 to 212°F) | 0.6°C (1.1°F) |
|
| -100.0 to 1000.0°C (-148 to 1832°F) | 0.2°C (0.4°F) |
|
R/S | 0 to 1767.0°C (32 to 3212°F) | 1.2°C (2.2°F) |
| | 0 to 1767.0°C (32 to 3212°F) | 1.2°C (2.2°F) |
|
| 600.0 to 800.0°C (1112 to 1472°F) | 1.2°C (2.2°F) |
|
B | 800.0 to 1000.0°C (1472 to 1832°F) | 1.3°C (2.4°F) |
|
| 1000.0 to 1820.0°C (1832 to 3308°F) | 1.5°C (2.7°F) |
|
C | 0 to 1000.0°C (32 to 1832°F) | 0.6°C (1.1°F) |
|
| 1000.0 to 2316.0°C (1832 to 3320°F) | 2.3°C (4.2°F) |
|
XK | -200.0 to 800.0°C (-328 to 1472°F) | 0.2°C (0.4°F) |
|
BP | 0 to 800.0°C (32 to 1472°F) | 0.9°C (1.6°F) |
|
| 800.0 to 2500.0°C (1472 to 4532°F) | 2.3°C (4.2°F) |
|
L | -200.0 to 0.0°C (-328 to 32°F) | 0.25°C (0.45°F) |
|
| 0 to 900.0°C (32 to 1652°F) | 0.2°C (0.4°F) |
|
U | -200.0 to 0.0°C (-328 to 32°F) | 0.5°C (0.9°F) |
|
| 0 to 600.0°C (32 to 1112°F) | 0.25°C (0.45°F) |
|
N | -200.0 to 0.0°C (-328 to 32°F) | 0.8°C (1.4°F) | | | 0 to 1300.0°C (32 to 2370°F) | 0.4°C (0.7°F) |
*All TC errors include CJC errors
CJC error outside of 23 ±
5°C is 0.05°C/°C (In °C add .2 for cold junction
compensation error.)
RTD
Range and Accuracy
|
RTD Type |
Range |
Accuracy* |
|
|
-200.0 to 100.0°C (-328 to 212°F) |
0.2°C (0.4°F) |
|
Pt100 (385) |
100.0 to 300.0°C (212 to 572°F) |
0.3°C (0.5°F) |
|
|
300.0 to 600.0°C (572 to 1112°F) |
0.4°C (0.7°F) |
|
|
600.0 to 800.0°C (1112 to 1472°F) |
0.5°C (0.9°F) |
|
|
-200.0 to 100.0°C (-328 to 212°F) |
0.8°C (1.4°F) |
|
Pt200 (385) |
100.0 to 300.0°C (212 to 572°F) |
0.9°C (1.9°F) |
|
|
300.0 to 630.0°C (572 to 1166°F) |
1.0°C (1.8°F) |
|
|
-200.0 to 100.0°C (-328 to 212°F) |
0.4°C (0.7°F) |
|
Pt500 (385) |
100.0 to 300.0°C (212 to 572°F) |
0.5°C (0.9°F) |
|
|
300.0 to 630.0°C (572 to 1166°F) |
0.6°C (1.1°F) |
|
|
-200.0 to 100.0°C (-328 to 212°F) |
0.2°C (0.4°F) |
|
Pt1000 (385) |
100.0 to 300.0°C (212 to 572°F) |
0.3°C (0.5°F) |
|
|
300.0 to 630.0°C (572 to 1166°F) |
0.4°C (0.7°F) |
|
|
-200.0 to 100.0°C (-328 to 212°F) |
1.4°C (2.5°F) |
|
Pt385-10 |
100.0 to 300.0°C (212 to 572°F) |
1.6°C (2.9°F) |
|
|
300.0 to 600.0°C (572 to 1112°F) |
1.8°C (3.2°F) |
|
|
600.0 to 800.0°C (1112 to 1472°F) |
2.0°C (3.6°F) |
|
|
-200.0 to 100.0°C (-328 to 212°F) |
0.4°C (0.7°F) |
|
Pt385-50 |
100.0 to 300.0°C (212 to 572°F) |
0.5°C (0.9°F) |
|
|
300.0 to 600.0°C (572 to 1112°F) |
0.6°C (1.1°F) |
|
|
600.0 to 800.0°C (1112 to 1472°F) |
0.7°C (1.3°F) |
|
|
-200.0 to 100.0°C (-328 to 212°F) |
0.2°C (0.4°F) |
|
Pt100 (3926) |
100.0 to 300.0°C (212 to 572°F) |
0.3°C (0.5°F) |
|
|
300.0 to 630.0°C (572 to 1166°F) |
0.4°C (0.7°F) |
|
|
-200.0 to 100.0°C (-328 to 212°F) |
0.2°C (0.4°F) |
|
Pt100 (3916) |
100.0 to 300.0°C (212 to 572°F) |
0.3°C (0.5°F) |
|
|
300.0 to 630.0°C (572 to 1166°F) |
0.4°C (0.7°F) |
|
Ni120 (672) |
-80.0 to 260.0°C (-112 to 500°F) |
0.2°C (0.4°F) |
|
Cu10 |
-100.0 to 260.0°C (-148 to 500°F) |
1.4°C (2.5°F) |
|
Cu50 |
-180.0 to 200.0°C (-292 to 392°F) |
0.4°C (0.7°F) |
|
Cu100 |
-180.0 to 200.0°C (-292 to 392°F) |
0.3°C (0.5°F) |
|
YSI400 |
15.00 to 50.00 (59 to 122°F) |
0.1°C (0.2°F) |
*Read Accuracy is based on 4-wire input. For 3-wire input add ±0.05
assuming all three RTD leads are matched.
Process Signals Range and Accuracy
|
Process Signals |
Read Accuracy* |
Source Accuracy* |
|
Current (mA) |
±0.015% of reading,±2 μA |
±0.015%
of reading, ±2 μA |
|
CPM |
±0.05% of reading,±1 LSD |
±0.05%
of reading |
|
Hz |
±0.05% of reading,±1 LSD |
±0.05%
of reading |
|
kHz |
±0.05% of reading, ±1 LSD |
±0.125%
of reading |
|
Ohms works with all pulsed transmitters down to 5 ms |
|
|
|
400 Ohm Range |
±0.025% of reading, ±0.05W |
±0.025% of reading, ±0.05W |
|
4000 Ohm Range |
±0.025% of reading, ±0.5W |
±0.025%
of reading, ±0.5W |
*MC-1210 Accuracy Specifications (23 °C ±5 °C unless otherwise noted)
|
| |
|
|
|
Each instrument includes Instruction Manual, Test Leads, Protective
Rubber Boot and NIST Certificate.
|
|
|
|
|
Multifunction Temperature and Process Calibrators,
Thermocouple and mA Calibrators,
Thermocouple and RTD Dry Block Calibrators,
Portable Infrared Thermometers,
Fixed Mounted Industrial Infrared Thermometers,
Thermocouple and RTD 2-wire Head Mounted Transmitters, DIN Rail Mounted Thermocouple and RTD Transmitters,
Temperature and Process Panel Meters, Temperature & Humidity Transmitters, Hand Held Digital Thermocouple Thermometers,
MIST Microprocessor Based Integral Transmitter RTD Temperature
Sensors,
Industrial Test tools and Multimeters, Indoor Air
Quality (IAQ) and Test Meters,
Hand Held Humidity and Air Flow Meters,
Industrial Portable
Refrigerant and Gas Leak Detection Meters,
Pressure Measurement and Calibration Instruments,
Boiler Flue Gas
Combustion Emission Analyzers,
Solar Radiation Meter
Temperature & Process Instruments Inc. * 1767 Central Park Avenue * Suite 112 * Yonkers
* NY * 10710 Phone: 1-914-673-0333 Fax: 1-866-292-1456 Email: sales@tnp-instruments.com© 2006 - 2012 Temperature & Process Instruments, Inc.
|
|
|
 |