Welcome to Temperature & Process Instruments, Inc.

MC1200 Multifunction Dual Display Temperature and Processs Calibrator

Home
Shop Online
Featured Products and Specials
Request a Quotation or Product Information
Microprocessor Integrated Sensor Transmitter (MIST) Temperature Sensors
Portable Non-Contact Infrared Thermometers
Industrial Fixed Mount Infrared Thermometers
Multifunction Temperature & Process Calibrators
Single Function Temperature & Process Calibrators
Dry Block Thermocouple & RTD Calibrators
Head Mounted Programmable Temperature Transmitters
DIN Rail Mounted Programmable Temperature Transmitters
Temperature & Process Panel Meters
Temperature & Humidity Transmitters
Hand Held Indoor Air Quality (IAQ) and Test Instruments
Hand Held Temperature, Humidity, and Air Flow Instruments
Industrial Test Tools
Portable Thermocouple Thermometers/Dataloggers
Industrial Refrigerant and Gas Leak Detection
Pressure Measurement and Calibration Instruments
New Products Coming Soon
Technical Information
Application Notes
Documentation and User Manuals
About Us
Shipping and Policies
Contact Us
Website Map

MC1200 High Accuracy Dual Display Multifunction Temperature and Process Calibrator with NIST Calibration Certificate

Precision Dual Display Multifunction Calibrator
MC1200 Multifunction Process Calibrator
MC1200 Multifunction Temperature Pressure and Process Calibrator.jpg
Supplied with Protective Rubber Boot
Prices Start at $1995.00

Click here to Order MC1200 Multifunction Temperature Pressure and Process Calibrator.gif

MC1200 Large Easy to Read Display
 MC1200 Multifunction Temperature Pressure and Process Calibrator Display.jpg

The MC1200 multifunction calibrator provides a feature set unmatched in high accuracy, handheld calibrators in its price range. The MC1200 calibrator provides the functions and accuracy associated with fixed-installation, laboratory instrument, and has everything needed for virtually any calibration task. Measure and source thermocouples, RTDs, current, voltage, and frequency, and source pulse trains.
A communications port compatible with both Fluke® 700 Series and Beta Calibrators pressure modules is provided, as is an isolated mA/V read-back circuit. Arrow keys, direct numeric keypad entry, and three software driven function buttons, plus a large backlit, menu-driven graphics display combine to provide a highly intuitive, simple yet powerful operator interface.
With a built-in 250 Ohm resistor for HART® compatibility, the MC1200 is compatibility with smart transmitters and PLCs, full fuse-less protection, are just some of the additional features that make the MC-1200 the single most indispensable tool available for virtually any calibration task.
Feature
  • Measure and source Thermocouples (13 types), RTDs
    (13 types), Ohms, current, voltage, frequency and source pulse trains signals
    Isolated mA/V read-back circuit for complete transmitter calibration
    • Built-in 250 Ohm resistor for HART
    ® compatibility
    Communication port compatible with both Fluke 700 Series and Beta Calibrator pressure modules
    • Built-in 24V supply can drive 4 to 20mA loops up to 1000 Ohms
    • Direct entry of custom RTD coefficients (Ro, A, B, C)
    • All source modes can be programmed with dedicated setpoints to speed calibration and linearity tests
    • Highest accuracy in class to 0.015% of reading
    • Meets CE requirements and is designed to IEC 1010 safety standards

    Click here to view a Flash Demonstration of the MC1200

    Specifications
    Environmental
    Operating Temperature: -10°C to +50°C (-14°F to 122°F)
    Storage Temperature: -20°C to +70°C (-4°F to 158°F)
    Stability: ±0.005% of reading/°C outside of 23 °C ± 5°C
    Power Requirements: 6Vdc; Batteries 4 AA alkaline (supplied) or optional rechargeable
    Mechanical
    Dimensions:
    8.7" H x 4.2" W x 2.3" D (220.9 x 106.6 x 58.4 mm)
    Weight: 30.5 ounces (863grams)

  • Signal Specifications
    Voltage Read and Source
    Source: 0.000 to 20.000Vdc
    Read: Isolated 0.000 to 30.000Vdc
    Non-Isolated 0.000 to 20.000Vdc
    Thermocouple
    Types and Ranges: See table below
    Accuracy: See Table Below
    Temperature scale: ITS90
    mV
    Read/Source: -10.000 to +75.000 mV
    Current (mA)
    Source: 0.000 to 24.000mA
    Read: Isolated: 0.000 to 24.000mA; 
    Non-Isolated: 0.000 to 24.000mA
    Frequency (1 to 20 V selectable amplitude)
    CPM Source and Read: 2.0 to 600.0 CPM
    Hz Source and Read: 1.0 to 1000.0 Hz
    kHz Source and Read: 1.0 to 10.00 kHz
    Pulse (Source only; 1 to 20 V selectable amplitude) 
    Pulses: 1 to 30,000.0 - 2 CPM to 10 kHz
    Ohms
    Source: 5.0 to 4000 Ohms
    Read: 0.00 to 4000.0 Ohms

    Thermocouple Range and Accuracy
    TC Type Range °C (°F) Accuracy*
     -210.0 to  0.0°C (-346 to 32°F)0.4°C (0.7°F)
    J0  to 800.0°C (32 to 1472°F)0.2°C (0.4°F)
     800.0 to 1200.0°C (1472 to 2192°F)0.3°C (0.5°F)
     -200.0 to 0.0°C (-328 to 32°F)0.6°C (1.1°F)
    K0 to 1000°C (32 to 1832°F)0.3°C (0.5°F)
     1000.0 to 1372.0°C (1832 to 2502°F)0.5°C (0.9°F)
    T-250.0 to 0.0°C (-418 to 32°F)0.6°C (1.1°F)
     0 to 400.0°C (32 to 752°F)0.2°C (0.4°F)
    E-250.0 to -100.0°C (-418 to 212°F)0.6°C (1.1°F)
     -100.0 to 1000.0°C (-148 to 1832°F)0.2°C (0.4°F)
    R0 to 1767.0°C (32 to 3212°F)1.2°C (2.2°F)
    S0 to 1767.0°C (32 to 3212°F)1.2°C (2.2°F)
     600.0 to 800.0°C (1112 to 1472°F)1.2°C (2.2°F)
    B800.0 to 1000.0°C (1472 to 1832°F)1.3°C (2.4°F)
     1000.0 to 1820.0°C (1832 to 3308°F)1.5°C (2.7°F)
    C0 to 1000.0°C (32 to 1832°F)0.6°C (1.1°F)
     1000.0 to 2316.0°C (1832 to 3320°F)2.3°C (4.2°F)
    XK-200.0 to 800.0°C (-328 to 1472°F)0.2°C (0.4°F)
    BP0 to 800.0°C (32 to 1472°F)0.9°C (1.6°F)
     800.0 to 2500.0°C (1472 to 4532°F)2.3°C (4.2°F)
    L-200.0 to 0.0°C (-328 to 32°F)0.25°C (0.45°F)
     0 to 900.0°C (32 to 1652°F)0.2°C (0.4°F)
    U-200.0 to 0.0°C (-328 to 32°F)0.5°C (0.9°F)
     0 to 600.0°C (32 to 1112°F)0.25°C (0.45°F)
    N-200.0 to 0.0°C (-328 to 32°F)0.8°C (1.4°F)
     0 to 1300.0°C (32 to 2370°F)0.4°C (0.7°F)
    *All TC errors include CJC errors CJC error outside of 23 ± 5°C is 0.05°C/°C
    (In °C add .2 for cold junction compensation error.)
     

    RTD Type

    Range

    Accuracy*

     

    -200.0 to 100.0°C (-328 to 212°F)

    0.2°C (0.4°F)

    Pt100 (385)

    100.0 to 300.0°C (212 to 572°F)

    0.3°C (0.5°F)

     

    300.0 to 600.0°C (572 to 1112°F)

    0.4°C (0.7°F)

     

    600.0 to 800.0°C (1112 to 1472°F)

    0.5°C (0.9°F)

     

    -200.0 to 100.0°C (-328 to 212°F)

    0.8°C (1.4°F)

    Pt200 (385)

    100.0 to 300.0°C (212 to 572°F)

    0.9°C (1.9°F)

     

    300.0 to 630.0°C (572 to 1166°F)

    1.0°C (1.8°F)

     

    -200.0 to 100.0°C (-328 to 212°F)

    0.4°C (0.7°F)

    Pt500 (385)

    100.0 to 300.0°C (212 to 572°F)

    0.5°C (0.9°F)

     

    300.0 to 630.0°C (572 to 1166°F)

    0.6°C (1.1°F)

     

    -200.0 to 100.0°C (-328 to 212°F)

    0.2°C (0.4°F)

    Pt1000 (385)

    100.0 to 300.0°C (212 to 572°F)

    0.3°C (0.5°F)

     

    300.0 to 630.0°C (572 to 1166°F)

    0.4°C (0.7°F)

     

    -200.0 to 100.0°C (-328 to 212°F)

    1.4°C (2.5°F)

    Pt385-10

    100.0 to 300.0°C (212 to 572°F)

    1.6°C (2.9°F)

     

    300.0 to 600.0°C (572 to 1112°F)

    1.8°C (3.2°F)

     

    600.0 to 800.0°C (1112 to 1472°F)

    2.0°C (3.6°F)

     

    -200.0 to 100.0°C (-328 to 212°F)

    0.4°C (0.7°F)

    Pt385-50

    100.0 to 300.0°C (212 to 572°F)

    0.5°C (0.9°F)

     

    300.0 to 600.0°C (572 to 1112°F)

    0.6°C (1.1°F)

     

    600.0 to 800.0°C (1112 to 1472°F)

    0.7°C (1.3°F)

     

    -200.0 to 100.0°C (-328 to 212°F)

    0.2°C (0.4°F)

    Pt100 (3926)

    100.0 to 300.0°C (212 to 572°F)

    0.3°C (0.5°F)

     

    300.0 to 630.0°C (572 to 1166°F)

    0.4°C (0.7°F)

     

    -200.0 to 100.0°C (-328 to 212°F)

    0.2°C (0.4°F)

    Pt100 (3916)

    100.0 to 300.0°C (212 to 572°F)

    0.3°C (0.5°F)

     

    300.0 to 630.0°C (572 to 1166°F)

    0.4°C (0.7°F)

    Ni120 (672)

    -80.0 to 260.0°C (-112 to 500°F)

    0.2°C (0.4°F)

    Cu10

    -100.0 to 260.0°C (-148 to 500°F)

    1.4°C (2.5°F)

    Cu50

    -180.0 to 200.0°C (-292 to 392°F)

    0.4°C (0.7°F)

    Cu100

    -180.0 to 200.0°C (-292 to 392°F)

    0.3°C (0.5°F)

    YSI400

    15.00 to 50.00 (59 to 122°F)

    0.1°C (0.2°F)

    *Read Accuracy is based on 4-wire input. For 3-wire input add ±0.05Ω
    assuming all three RTD leads are matched.

     
     

    Process Signals

    Read Accuracy*

    Source Accuracy*

    Current (mA)

    ±0.015% of reading,±2 μA

    ±0.015% of reading, ±2 μA

    CPM

    ±0.05% of reading,±1 LSD 

    ±0.05% of reading

    Hz

    ±0.05% of reading,±1 LSD

    ±0.05% of reading

    kHz

    ±0.05% of reading, ±1 LSD 

    ±0.125% of reading

    Ohms works with all pulsed transmitters down to 5 ms

     

     

    400 Ohm Range

    ±0.025% of reading, ±0.05W

    ±0.025% of reading, ±0.05W

    4000 Ohm Range

    ±0.025% of reading, ±0.5W

    ±0.025% of reading, ±0.5W

    *MC-1200 Accuracy Specifications (23 °C ±5 °C unless otherwise noted)

    MC1200 Multifunction Temperature Pressure and Process Calibrator.jpg

    Each instrument includes Instruction Manual, Test Leads, Protective Rubber Boot and NIST Certificate.

    pdficon.gif

    Download the MC1200 Specification Sheet


    Temperature & Process Instruments Inc. * 1767 Central Park Avenue * Suite 112 * Yonkers  * NY * 10710
    Phone: 1-914-673-0333 Fax: 1-866-292-1456 Email:
    sales@tnp-instruments.com
    © 2006 - 2010 Temperature & Process Instruments, Inc.