MC-1010 Multifunction calibrator provides
high accuracy calibration, common DMM functions including read and source thermocouples, RTDs, Ohms, current, pressure, frequency
and test continuity. |
|
|
Special Introductory Price $1354.00 save 5% |
MC-1010 Calibrator Supplied with Protective Rubber Boot
|
 |
Prices Start at $1425.00
Special Introductory Price $1354.00
save 5% |
 |
The MC-1010 Multifunction Calibrator with the
New ClearBrite™ High Graphic Display
provides the combination of a high accuracy calibrator and common Digital Multi-Meter (DMM) functions. This single instrument will calibrate virtually any process
device. Capable of reading and simulating Thermocouples, RTDs, Ohms, Voltage, Current, Frequency, Pressure and test continuity
as well. The MC1010 is compatible with both Fluke 700 Series and
BETA pressure modules
with the addition of a simple connector/adapter. The MC1010 features a
simple user interface, large display, and an RS232 interface.
Features
• New ClearBrite™ High Graphic Display
• 3 Key Martel Menu System
• ±0.4°C thermocouple/±0.3°C RTD accuracy
• ±0.015% of reading electrical accuracy
• Ten (10) T/C types and eight (8) RTD types, plus YSI 400 Thermistors
• Read and source modes
• Full function 4 to 20mA read, source, simulate, and read/power modes with ±0.015% of reading accuracy
• Source or read 0 to 20 Volts (±0.015% of reading accuracy)
• Measure 0 to 250 VDC or VAC
• Direct keyboard entry enables quick output changes
• Store up to nine (9) setpoints for each output function
• RTD function compatible with all pulsed transmitters
• RS232 interface
|
Specifications
Input Ranges: See Tables below
Accuracy: See Tables below
Temperature scale: ITS90
Continuity: 0 to 400.0 Ohms; audible tone when under 10 Ohms
mA Compliance: Up to 1,000Ω load
Voltage Drive Capability: 1mA
RTD IEX-Range: 0.01mA to 3mA RTD Frequency Response: 10ms, works with all pulsed transmitters
Operating Temperature: -10° to +50°C (14°F to 122°F)
Storage Temperature: -20° to 70°C (-4° to + 158°F)
Power Requirements: 6 VDC Batteries 4 AA alkaline batteries, 25 hours typical operating time
Dimensions: 8.5" H x 4.8" W x 2.1" D (22 x 12 x 5.3cm)
Weight: 1.8 lbs (0.82 kg)
|
MC-1010 ClearBrite™ High Graphic Display
 |
Thermocouple Range and Accuracy
Table
|
Thermocouple Read and Source (All errors included) |
|
Type |
Min/Max Temperature Range |
Accuracy |
|
J |
-200.0 to 0.0°C (-328 to 32°°F) |
0.6°C (1.1°F) |
|
|
0.0 to 1200.0°C (32 to 2192°F) |
0.4°C (0.7°F) |
|
K |
-200.0 to 0.0°C (-328 to 32°F) |
0.8°C (1.4°F) |
|
|
0.0 to 1370.0°C (32 to 2498°F) |
0.5°C (0.9°F) |
|
T |
-200.0 to 0.0°C (-328 to 32°F) |
0.8°C (1.4°F) |
|
|
0.0 to 400.0°C (32 to 752°F) |
0.5°C (0.9°F) |
|
E |
-200.0 to 0.0°C (-328 to 32°F) |
0.5°C (0.9°F) |
|
|
0.0 to 950.0°C (32 to 1752°F) |
0.4°C (0.7°F) |
|
R |
-20 to 0.0°C (-4 to 32°F) |
2.49°C (4.5°F) |
|
|
0 to 500 (32 to 932°F) |
1.7°C (3.1°F) |
|
|
500 to 1750 (932 to 3182°F) |
1.3°C (2.3°F) |
|
S |
-20 to 0 (-4 to 32°F) |
2.4°C (4.3°F) |
|
|
0 to 500 (32 to 932°F) |
1.7°C (3.1°F) |
|
|
500 to 1750 (932 to 3182°F) |
1.4°C (2.5°F) |
|
B |
600 to 800 (1112 to 1472°F) |
2.1°C (3.8°F) |
|
|
800 to 1010 (1472 to 1832°F) |
1.7°C (3.1°F) |
|
|
1010 to 1800 (1832 to 3272°F) |
1.3°C (2.3°F) |
|
L |
-200 to 0.0°C (-328 to 32°F) |
0.45°C (0.8°F) |
|
|
0.0 to 900.0°C (32 to 1652°F) |
0.4°C(0.7°F) |
|
U |
-200 to 0.0°C (-328 to 32°F) |
0.7°C (1.3°F) |
|
|
0.0 to 400.0°C (32 to 752°F) |
0.45°C (0.8°F) |
|
N |
-200 to 0.0°C (-328 to 32°F) |
1.1°C (2.0°F) |
|
|
0.0 to 1300.0°C (32 to 2372°F) |
0.6°C (1.1°F) |
|
mV Read/Source |
-10.00 to 75.00 mV |
0.015% ±.02 mV |
|
RTD Read and Source |
|
Type |
Min/Max Temperature Range |
Accuracy |
|
Pt100 (385) |
-200.0 to 800.0°C (-328 to 1472°F) |
0.33°C (0.6°F) |
|
Pt100(3926) |
-200.0 to 630.0°C (-328 to 1166°F) |
0.3°C (0.5°F) |
|
Pt100(3916) |
-200.0 to 630.0°C (-328 to 1166°F) |
0.3°C (0.5°F) |
|
Pt200(385) |
-200.0 to 630.0 (-328 to 1166°F) |
0.8°C (1.4°F) |
|
Pt500(385) |
-200.0 to 500.0°C (-328 to 932°F) |
0.3°C (0.5°F) |
|
|
500.0 to 630.0°C (932F to 1166°F) |
0.4°C (0.7°F) |
|
Pt1010(385) |
-200.0 to 100.0°C (-328 to 212°F) |
0.2°C (0.5°F) |
|
|
100.0 to 630.0°C (212 to 1166°F) |
0.3°C (0.4°F) |
|
Cu10 |
-100.0 to 250.0 (-148 to 482°F) |
2.2°C (4.0°F) |
|
Ni120 (672) |
-80.0 to 260.0°C (-112 to 500°F) |
0.2°C (0.5°F) |
|
YSI400 |
15.00 to 50.00°C ( (58 to 122°F) |
0.05°C (0.09°F) |
|
Process Signal Type |
Min - Max
Range |
Accuracy (% of reading ±counts) |
|
V Read (low) |
0.000 to 20.000 |
0.015% ±2 |
|
VDC Read (high) |
0.0 to 250.0 |
0.05% ±2 |
|
VAC Read (high) |
0.0 to 250.0 |
0.5% ±2 |
|
V Source |
0.000 to 20.000 |
0.015% ±2 |
|
mV Read |
-10.00 to 75.00 |
0.015% ±2 |
|
mV Source |
-10.00 to 75.00 |
0.015% ±2 |
|
mA Read |
0.000 to 24.000 |
0.015% ± 2 |
|
mA Source |
0.000 to 24.000 |
0.015% ± 2 |
|
CPM Source |
2.0 to 1010.0 |
0.05% |
|
Hz Source |
1 to 1010 |
0.05% |
|
KHz Source |
1.0 to 10.0 |
0.25% |
|
CPM Read |
0.0 to 1010.0 |
0.05% ± 1 |
|
Hz Read |
0.0 to 1010.0 |
0.05% ± 1 |
|
KHz Read |
0.00 to 10.00 |
0.05% ± 1 |
|
|
Min - Max
Range |
Accuracy |
|
Ohms Read (low) |
0.00 to 400.00 |
0.1W |
|
Ohms Read (high) |
400.0 to 1500.0 |
0.5W |
|
|
1500.1 to 3200.0 |
1.0 W |
|
Signal Type |
Minimum Range |
Maximum Range |
Excitation Current |
Accuracy |
|
Ohms Source (low) |
5.00 |
400.00 |
0.1 to 0.5 mA |
0.15 ohm |
|
|
5.00 |
400.00 |
0.5 to 3 mA |
0.1 ohm |
|
Ohms Source (high) |
400.0 |
1500.0 |
0.05 to 0.8 mA |
0.5 ohm |
|
|
1500.0 |
3200.0 |
0.05 to 0.4 mA |
1.0 ohm |
|
|
Each instrument includes Instruction Manual, Test Leads, Protective Rubber Boot and NIST Calibration Certificate.
|
|
|
|
|
Multifunction Temperature and Process Calibrators,
Thermocouple and mA Calibrators,
Thermocouple and RTD Dry Block Calibrators,
Portable Infrared Thermometers,
Fixed Mounted Industrial Infrared Thermometers,
Thermocouple and RTD 2-wire Head Mounted Transmitters, DIN Rail Mounted Thermocouple and RTD Transmitters,
Temperature and Process Panel Meters, Temperature & Humidity Transmitters, Hand Held Digital Thermocouple Thermometers,
MIST Microprocessor Based Integral Transmitter RTD Temperature
Sensors,
Industrial Test tools and Multimeters, Indoor Air
Quality (IAQ) and Test Meters,
Hand Held Humidity and Air Flow Meters,
Industrial Portable
Refrigerant and Gas Leak Detection Meters,
Pressure Measurement and Calibration Instruments,
Boiler Flue Gas
Combustion Emission Analyzers, Solar Radiation Meter
Temperature & Process Instruments Inc. * 1767 Central Park Avenue * Suite 112 * Yonkers
* NY * 10710 Phone: 1-914-673-0333 Fax: 1-866-292-1456 Email: sales@tnp-instruments.com© 2006 - 2012 Temperature & Process Instruments, Inc.
|
|
|
 |