Welcome to Temperature & Process Instruments, Inc.

DMC1400/MC1000/MC1200 Multifunction Calibrator Pressure Gauges

Home
Shop Online
Featured Products and Specials
Request a Quotation or Product Information
Microprocessor Integrated Sensor Transmitter (MIST) Temperature Sensors
Portable Non-Contact Infrared Thermometers
Industrial Fixed Mount Infrared Thermometers
Multifunction Temperature & Process Calibrators
Single Function Temperature & Process Calibrators
Dry Block Thermocouple & RTD Calibrators
Head Mounted Programmable Temperature Transmitters
DIN Rail Mounted Programmable Temperature Transmitters
Temperature & Process Panel Meters
Temperature & Humidity Transmitters
Hand Held Indoor Air Quality (IAQ) and Test Instruments
Hand Held Temperature, Humidity, and Air Flow Instruments
Industrial Test Tools
Portable Thermocouple Thermometers/Dataloggers
Industrial Refrigerant and Gas Leak Detection
Pressure Measurement and Calibration Instruments
New Products Coming Soon
Technical Information
Application Notes
Documentation and User Manuals
About Us
Shipping and Policies
Contact Us
Website Map

Martel BetaGauge Pressure Modules High Accuracy Digital Modules

MC1200/MC1000/DMC1400 Pressure Module
MC1200_PRESSURE.jpg
Click Here to Order IRtec P2000+ Mk2 High Temperature Portable Documenting Infrared Thermometer.jpg
Pressure Modules Prices Start at $850.00

BPPA 100 BetaPort-P Pressure Module Adapter $250.00

MC1200MC1000 and DMC1400 Calibrators Sold Separately

The DMC1400, MC1200 and MC1000 Multifunction Calibrators can be used to measure pressure by using the BPPA-100 BETA Port Pressure Adapter. 29 standard BETA Calibrators pressure modules, covering gauge, vacuum, absolute, compound, and differential measurements are available. With the Model BPPA-100 BETA Port Pressure Adapter, the modules are fully compatible with the DMC1400, MC1200 and MC1000 Multifunction Calibrators. Pressure ranges may be displayed in any of 13 user-selectable units. Water density correction factors of 4°C, 20°C, or 60°F can be selected for either water column unit. The choice of pressure unit may be restricted by limitations on resolution of the instrument display.

Features
• 29 standard ranges
• Gauge, vacuum, absolute, compound, and differential measurements
• Accuracy specified over 15°C to 35°C range
• Isolated and non-isolated measurements, range dependant

For more information on the Beta Pressure modules, please contact us.

Available Ranges: (*Isolated=316SS Wetted Parts; Non-isolated=dry media only!!)

Model
Number

PARAMETER
RANGE

FULL SCALE
ACCURACY

OVER
PRESSURE

 

Gauge (PSIG)

910331-003

0 to 0.3 (0 to .02mBar)

±0.1

400%

910331-001

0 to 1 (0 to 7mBar)

±0.05

400%

910331-005

0 to 5 (0 to 350mBar)*

±0.025 ±0.003 psi

400%

910331-007

0 to 7.2 (0 to 500mBar)*

±0.035±0.0025 psi

300%

910331-010

0 to 10 (0 to 700mBar)*

±0.025 ±0.0025 psi

300%

910331-015

0 to 15 (0 to 1 Bar)*

±0.025 ±0.0025 psi

300%

910331-030

0 to 30 (0 to 2 Bar)*

±0.025

300%

910331-050

0 to 50 (0 to 3.5 Bar)*

±0.03

300%

910331-100

0 to 100 (0 to 7 Bar)*

±0.025

300%

910331-150

0 to 150 (0 to 10 Bar)*

±0.035

200%

910326-300

0 to 300 (0 to 20 Bar)*

±0.025

200%

910326-500

0 to 500 (0 to 35 Bar)*

±0.025

200%

910326-301

0 to 1000 (0 to 70 Bar)*

±0.025

200%

910326-315

0 to 1500 (0 to 100 Bar)*

 ±0.035

200%

910326-303

0 to 3000 (0 to 200 Bar)*

±0.1

200%

910326-305

0 to 5000 (0 to 340 Bar)*

±0.1

200%

910331-10K

0 to 10000 (0 to 700 Bar)*

±0.1

150%

 

Vacuum (PSIG)

910327-005

0 to -5 (0 to -350 mBar)

±0.025%, ±0.003 psi

400%

910327-015

0 to -15 (0 to -1 mBar)

±0.025%, ±0.0025 psi

300%

 

Absolute (PSIA)

910332-015

0 to 15 (0 to 1 Bar)*

±0.025%, ±0.0025 psi

300%

910332-030

0 to 30 (0 to 2 Bar)*

±0.025%

300%

910332-050

0 to 50 (0 to 3.5 Bar)*

±0.03%

300%

910332-100

0 to 100 (0 to 7 Bar)*

±0.025%

300%

910332-300

0 to 300 (0 to 20 Bar)*

±0.025%

200%

 

Differential (PSID)

910329-005

0 to 5 (0 to 350 mBar)

±0.025%, ±0.003 psi

400%

910329-030

0 to 30 (0 to 2 Bar)

±0.025%

300%

910329-050

0 to 50 PSID (0 to 3.5 Bar)

±0.03%

300%

 

Compound (PSIG)

910333-015

-15 to 15 (-1 to 1 Bar)

±0.025%, ±0.0025 psi

300%

910333-030

-15 to 30 (-1 to 2 Bar)

±0.025%, ±0.0025 psi

300%

* Isolated 316SS Wetted Parts, all others Non-isolated, dry media only.

Notes:

1. Accuracy is percent of full scale range, over the 15 °C to 35 °C temperature range. Includes the pressure/temperature hysteresis in psi, where listed, for six months from date of last calibration. The accuracy statement shown in the specification table is the base accuracy from 15 °C to 35 °C. Outside this temperature range, add an additional ±0.0015% of FS per °C. To calculate the allowed deviation of a particular BETA Pressure Module, use the following formula: Deviation = ±%FS , ±T/P H, ±tempco where ±T/P H = thermal/pressure hysteresis in psi where applicable, And ±tempco = ±0.0015% FS/°C when the temperature is outside the 15-35 °C temperature range2. The Gauge, Vacuum, and Compound type range measurements are relative to atmospheric pressure. The Absolute type is a measurement made relative to absolute zero (perfect vacuum). The Differential type is a measurement made relative to the pressure applied to the low-pressure port of the module.

3. Units for display: pounds per square inch (psi), millibars (mbar), kilopond per square centimeter (kp/cm2, also kg/cm2), atmospheres physical (Atmos), kilopascals (kPa), MegaPascals (MPa), inches of Mercury @ 0 °C (InHg), millimeters of Mercury @ 0 °C (mmHg), inches of water column (InWC), centimeters of water column (cmWC), or one user-defined pressure unit.

4. These extended ranges are drerated because the calibrated range of the module does not match the range of the sensor.

5 The maximum static pressure is 200 psig (14 bar).

6. Relative to the calibration standard.

7. Thermal and pressure hysteresis = 0.0025 PSI (0.1724 mBar)

8. Thermal and pressure hysteresis = 0.0030 PSI (0.2068 mBar); all other ranges = no hysteresis

9. 0 to 7.2 PSI, 0 to 150 PSI, and 0 to 1500 PSI are extended ranges.

10. Gauge, Absolute, and Compound types are isolated and accept any media compatible with 316SS. Vacuum and Differentiated types are compatible with pressure media that are clean, dry, non-corrosive air or gas.


Temperature & Process Instruments Inc. * 1767 Central Park Avenue * Suite 112 * Yonkers  * NY * 10710
Phone: 1-914-673-0333 Fax: 1-866-292-1456 Email:
sales@tnp-instruments.com