Welcome to Temperature & Process Instruments, Inc.

MicroCal 200/200+ Range and Accuracy Tables

Home
Shop Online
Featured Products and Specials
Request a Quotation or Product Information
Microprocessor Integrated Sensor Transmitter (MIST) Temperature Sensors
Portable Non-Contact Infrared Thermometers
Industrial Fixed Mount Infrared Thermometers
Multifunction Temperature & Process Calibrators
Single Function Temperature & Process Calibrators
Dry Block Thermocouple & RTD Calibrators
Head Mounted Programmable Temperature Transmitters
DIN Rail Mounted Programmable Temperature Transmitters
Temperature & Process Panel Meters
Temperature & Humidity Transmitters
Hand Held Indoor Air Quality (IAQ) and Test Instruments
Hand Held Temperature, Humidity, and Air Flow Instruments
Industrial Test Tools
Portable Thermocouple Thermometers/Dataloggers
Industrial Refrigerant and Gas Leak Detection
Pressure Measurement and Calibration Instruments
New Products Coming Soon
Technical Information
Application Notes
Documentation and User Manuals
About Us
Shipping and Policies
Contact Us
Website Map
MicroCal 200/200+ 2-Channel Multifunction Calibrator

MicroCal 200/200+/2000 Portable Multifunction Temperature and Process Calibrator.jpg
MicroCal 200+ Shown with Expansion PC Card Slot
MicroCal 200 Series Dicontinued Product
See New 3001 Benchtop Calibrator

. Simultaneous Indication of Input and Output with Engineering Units

. Large Easy to Read LCD Display

. Large Easy to Use Keys

. Change Parameter Fast Using Front Keypad

. Isolated Input Channel 2 and Output Channel 1

. Real Time Graphing and Data Logging Capability

Click here to Order MicroCal 200/200+/2000 Portable Multifunction Temperature and Process Calibrator.gif

Thermocouple Range and Accuracy Table

Thermocouple

 

 

Microcal 200

Microcal 200+

Type

Range

Resolution

Accuracy*

Accuracy*

J

-210 to 1200°C

0.1°C

±(0.02% +0.1°C)

±(0.01% +0.1°C)

 

-346 to 2192°F

0.1°F

±(0.02% +0.18°F)

±(0.01% +0.18°F)

K

-270 to 1370°C

0.1°C

±(0.02% +0.1°C)

±(0.01% +0.1°C)

 

-454 to 2498°F

0.1°F

±(0.02% +0.18°F)

±(0.01% +0.18°F)

T

-270 to 400°C

0.01°C

±(0.02% +0.1°C)

±(0.01% +0.1°C)

 

-454 to 752°F

0.1°F

±(0.02% +0.18°F)

±(0.01% +0.18°F)

E

-270 to 1000°C

0.1°C

±(0.02% +0.1°C

±(0.01% +0.1°C)

 

-454 to 1832°F

0.1°F

±(0.02% +0.18°F)

±(0.01% +0.18°F)

R/S

-50 to 1760°C

0.1°C

±(0.02% +0.2°C)

±(0.01% +0.2°C)

 

-58 to 3200°F

0.1°F

±(0.02% +0.36°F)

±(0.01% +0.36°F)

B

50 to 1820°C

0.1°C

±(0.02% +0.3°C)

±(0.01% +0.3°C)

 

122 to 3308°F

0.1°F

±(0.02% +0.54°F)

±(0.01% +0.54°F)

C

0 to 2300°C

0.1°C

±(0.02% +0.2°C)

±(0.01% +0.2°C)

 

32 to 4172°F

0.1°F

±(0.02% +0.36°F)

±(0.01% +0.36°F)

G/D

0 to 2300°C

0.1°C

±(0.02% +0.3°C)

±(0.01% +0.3°C)

 

32 to 4172°F

0.1°F

±(0.02% +0.54°F)

±(0.01% +0.54°F)

U

-200 to 400°C

0.1°C

±(0.02% +0.1°C)

±(0.01% +0.1°C)

(J DIN)

-328 to 752°F

0.1°F

±(0.02% +0.18°F)

±(0.01% +0.18°F)

L

-200 to 760°C

0.1°C

±(0.02% +0.1°C)

±(0.01% +0.1°C)

(T DIN)

-328 to 1400°F

0.1°F

±(0.02% +0.18°F)

±(0.01% +0.18°F)

N

-270 to 1300°C

0.1°C

±(0.02% + 0.1°C)

±(0.01% +0.1°C)

 

-454 to 2372°F

0.1°F

±(0.02% +0.18°F)

±(0.01% +0.18°F)

F

0 to 1400°C

0.1°C

±(0.02% +0.1°C)

±(0.01% +0.1°C)

(Platinel II)

32 to 2552°F

0.1°F

±(0.02% +0.18°F)

±(0.01% +0.18°F)

 
RTD Range and Accuracy Table

RTD

 

 

Microcal 200

Microcal 200+

Type

Range

Resolution

Accuracy*

Accuracy*

Pt100

-200 to 850°C

0.01°C

±(0.02% +0.05°C)

±(0.01% +0.05°C)

 385, 391, 3926

-328 to 1562 °F

0.1°F

±(0.02% +0.09°F)

±(0.01% +0.09°F)

Pt100

-200 to 650°C

0.01°C

±(0.02% +0.05°C)

±(0.01% +0.05°C)

 3902

-328 to 1202°F

0.1°F

±(0.02% +0.09°F)

±(0.01% +0.09°F)

Pt100

-200 to 600°C

0.01°C

±(0.02% +0.05°C)

±(0.01% +0.05°C)

 3916, 3923

-328 to 1112°F

0.1°F

±(0.02% +0.09°F)

±(0.01% +0.09°F)

Pt200

-200 to 850°C

0.1°C

±(0.02% +0.15°C)

±(0.01% +0.15°C)

 

-328 to 1562°F

0.1°F

±(0.02% +0.27°F)

±(0.01% +0.27°F)

Pt500

-200 to 850°C

0.1°C

±(0.02% +0.1°C)

±(0.01% +0.1°C)

 

-328  to 1562°F

0.1°F

±(0.02% +0.18°F)

±(0.01% +0.18°F)

Pt1000

-200 to 850°C

0.01°C

±(0.02% +0.1°C)

±(0.01% +0.1°C)

 385, 391

-328 to 1562°F

0.1°F

±(0.02% +0.18°F)

±(0.01% +0.18°F)

Cu10

-70 to 150°C

0.1°C

±(0.02% +0.4°C)

±(0.01% +0.4°C)

 

-94 to 302°F

0.1°F

±(0.02% +0.72°F)

±(0.01% +0.72°F)

Cu100

-180 to 150°C

0.1°C

±(0.02% +0.05°C)

±(0.01% +0.05°C)

 

-292  to 302°F

0.1°F

±(0.02% +0.09°F)

±(0.01% +0.09°F)

Ni100

-60 to 180°C

0.1°C

±(0.02% +0.05°C)

±(0.01% +0.05°C)

 

-76 to 356°F

0.1°F

±(0.02% +0.09°F)

±(0.01% +0.09°F)

Ni120

0 to 150°C

0.1°C

±(0.02% +0.05°C)

±(0.01% +0.05°C)

 

32 to 302°F

0.1°F

±(0.02% +0.09°F)

±(0.01% +0.09°F)

 
Process Signals Range and Accuracy Table 

Process

 

 

Microcal 200

Microcal 200+

Signal Type

Range

Resol.

Accuracy*

Accuracy*

Ohms IN

0 to 500 Ohms

1 mOhms

±(0.01% +12mOhms)

±(0.02% +12mOhms)

 

0 to 5000 Ohms

0.01 Ohms

±(0.01% +120mOhms)

±(0.02% +120mOhms)

Ohms OUT

0 to 500 Ohms

1 mOhms

±(0.01% +20mOhms)

±(0.02% +20mOhms)

 

0 to 5000 Ohms

0.01 Ohms

±(0.01% +200mOhms)

±(0.02% +200mOhms)

mA (In)

-5 to +50mA

0.1µA

±(0.01% +0.4µA)

±(0.02% +0.4µA)

mA (Out)

0 to +50mA

0.1µA

±(0.01% +0.4µA)

±(0.02% +0.4µA

mV (L)

-20 to +200mV

1µV

±(0.01% +2µV)

±(0.02% +2µV)

mV (H)

-0.2 to +2 V

10µV

±(0.01% +10µV

±(0.02% +10µV)

V

-2 to +20 V

0.1mV

±(0.01% +0.08 mV)

±(0.02% +0.08mV)

 

1 to 200 Hz

0.001 Hz

±(0.005% +0.001 Hz)

 

Frequency

1 to 2,000 Hz

0.01

±(0.005% +0.001 Hz)

 

 

1 to 20,000 Hz

0.1 Hz

±(0.005% +0.001 Hz)

 

Pulse counter

0 to 106 counts

1 count

infinite

infinite

Pulse (Out)

0 to 6,000 pulse/min

1 pulse/min

1 pulse/min

1 pulse/min

 

0 to 36,000 pulse/h

1 pulse/hr

1 pulse/min

1 pulse/min

 Note: The MicroCal 200/200+ relative accuracies shown above are stated for 360 days and the operative conditions are from +64°F to +82°F.  Typical 90 days relative accuracy can be estimated by dividing the "% of reading" specifications by 1.6. Typical 2 years relative accuracy can be estimated by multiplying the “% of reading" specifications by
1.4. 
All input ranges: additional error ±1 digit.

MicroCal 200/200+/2000 Portable Multifunction Temperature and Process Calibrator.jpg
MicroCal 200+ Shown
Click Here To Order: Model Microcal 200 or 200+ Multifunction Calibrator. Please call for Price and Availability

Each instrument includes USB Serial Interface, Real time clock and internal memory, Soft Vinyl protection case, NIST Certificate of Calibration, Instruction Manual, Spare fuses and Logman, LinMan, Calpman PC software.