IN/OUT
parameters: |
Signal type: mV, V, mA, W, KW, Frequency, Pulses |
|
|
Thermocouples type: J, K, T, R, S, B, N, C, E,
U, L, F, G, D |
|
|
Resistance (RTD) thermometers: Pt100 IEC, OIML,
USLAB,
US, SAMA, JIS, Pt200, 500, 1000, 1000 OIML, Ni100, Ni120, Cu10,
Cu100 |
|
Reference
junction compensation: |
Internal automatic: from -10 °C to +55 °C (14°F
to 130°F); |
|
|
external adjustable: from -50 °C to +100 °C (-58°F
to 210°F); |
|
|
remote with external Pt100: from -10°C to +100
°C (14°F to 210°F) |
|
Rj compensation
drift: |
± 0.015°C/°C (from -10 °C to +55 °C) |
|
Rj compensation
error: |
Internal: ±0.15°C (±0.3°F) |
|
|
Remote: ±0.3°C (±0.6°F) |
|
Common
mode rejection: |
>140 dB at ac operation |
|
Normal
mode rejection: |
>70 dB at 50 or 60 Hz |
|
Temperature
stability MicroCal 200/200+: |
For temperature exceeding the band +18°C to +28°C
(from +64 °C to +84 °F) full scale: ± 8ppm/°C zero: ± 0.2 V /°C |
|
Output
impedance (emf output): |
< 0.5 with 0.5mA maximum current |
|
Input
impedance (mV, V and Tc ranges): |
>10 MW |
|
Input
impedance (mA ranges): |
<140W @ 1mA |
|
Source
resistance effects: |
±1µV error for 1000 source resistance |
|
RTD and
simulation excitation current: |
From 0.01 to 5mA |
|
RTD and
measurement excitation current: |
~ 0.4mA@ 400 |
|
RTD connection: |
2, 3, and 4 wires |
|
RTD cable
compensation: |
Up to 100W (each wire) |
|
RTD cable
compensation error (Pt100): |
±0.005°C/W of total wire |
|
Maximum
load resistance: |
1000W @ 20mA |
|
Display: |
Graphic LCD 240 x 64 dots display with LED backlight
device |
|
Measurement
sampling time: |
250 ms |
|
Output
noise (at 300 Hz): |
<2µVpp for ranges up to 200 mV fs., |
|
|
<10µVpp for ranges up to 2 V fs. |
|
|
<80µVpp for ranges up to 20 V f.s. |
|
Digital
interface: |
Full bidirectional TTL (a RS232 adapter normal
or insulated, is available as an option) |
|
Channel
1_Channel 2 insulation: |
50Vdc |
|
Calculation
functions: |
Hold, max, min, offset, average |
|
Selection
°C/°F/K: |
Through the configuration procedure |
|
In/Out
data memory: |
20 data with manual or automatic recall |
|
Logging
mode: |
1500 input data items (optional memory card for
memory extension) |
|
Convert
function: |
Displays the electrical equivalent of the engineering
unit |
|
Scale
factor: |
5 different settings with zero and span programmable
within -399999 and +999999 |
|
Square
root: |
In combination with scale factor |
|
Calibration: |
Self learning technique with automatic procedure |
|
Power
supply: |
External charger and rechargeable Ni-Cd battery |
|
Self contained
operation: |
6h on Thermocouple and mV input/output (backlight
Off) |
|
Recharging
time: |
3.5h with 20 mA simulation (backlight Off) |
|
|
5h at 90% and 6h at 99% with instrument switched
off. |
|
|
The battery charging is active only with the instrument
switched off. |
|
Line operation: |
100 - 120 - 230 Vac through the external battery
charger |
|
Line transformer
insulation: |
2500Vac |
|
Firmware
release identification: |
Release code on the display |
|
Operating
environment temperature range: |
From -10 °C to +55 °C (from 14 °C to 130 °F) |
|
Storage
temperature range: |
From -30 °C to +60 °C (from -22 °C to 140 °F) |
|
Case: |
Injection molded ABS with internal metal coating |
|
Dimensions: |
264 x 96 x 172 mm (10.4”x3.8”x6.8”)
DIN size |
|
Weights: |
net: 8.8 lb. gross: 12.1 lb. |