Log In        Register

BTU 900-2 Combustion Flue Gas Analyzer with O2, CO and CO2 Measurements

Now Includes Automatic Outdoor Air Temperature Saving for ALL 90%+ Systems & Condensing Systems for TRUE Efficiency Calculations
NO MORE SPECIAL SEPARATE PROBES NEEDED For High Efficiency Systems!

BTU 900-2 Combustion Flue Gas Analyzer with O2, CO and CO2 Measurements
    Price Starting At: $999.00

    Overview

    The BTU 900-2 multifunctional combustion analyzer is designed to maximum your boiler, furnace combustion efficiency, easily set-up, install, and properly service any residential and or light commercial boilers and burners. The BTU 900-2 meet and exceed the everyday needs of heating service engineers, gas installers, plumbers and HVAC Service Professionals. Accurate, compact, rugged, easy to use; the BTU 900-2 is the ideal solution to monitor your boiler process. These gas analyzers measure, display and print combustion efficiency, O2, CO, CO2, along with ALL of the necessary temperature, draft, and pressure measurements.
    Features
    • New Bluetooth Communications now Included
    • Combustion Analyzer for Oxygen (O2), Carbon Monoxide (CO) and Carbon Dioxide (CO2), Excess Air, Efficiency along with all of the necessary temperature, draft, and pressure measurements
    • Carbon Monoxide (CO) Leak Detector
    • Thermometer (Ambient, Flue & Incoming Air)
    • 600 Internal Test Memory and PC Software Included to download tests & customer database (keep records, export & email)
    • Field-Replaceable, Pre-Calibrated Sensors eliminates any downtime!
    • Bluetooth Connectivity
    • PC Software Included to download tests & customer database (keep records, export & email)
    • Unbreakable Metal Connections (No plastic breakable pieces
    • Easy to use with direct ONE Button Operation
    • Li-Ion Rechargeable Battery and Charger Included
      Shipping Estimated Shipping 2 to 3 Days

    BTU900-2 Combustion Analyzer Measurement Specifications
    Parameter Sensor Range Resolutoin Accuracy
    Carbon Monoxide (CO) Electrochemical 0 to 8,000 ppm 1 ppm ±±10 ppm <400ppm
    ±5% rdg up to 2000 ppm
    ±10% rdg for >2000 ppm
    Oxygen (02) Electrochemical 0 to 25% 0.1% ±0.2% volume
    Carbon Dioxide (CO2) Calculated 0 to 99.9% 0.1%
    Nitric Oxide (NO) NA
    Nitrogen Oxides (NOX) NA
    Temperature Air Pt100 -10 to 212°F (-23 to 100°C) 0.1°F or .5°C ± 1°F
    Temperature gas -10 to 1830°F (-23°C to 999°C) 1°F or °C ± 2°F
    Differential Temperature Calculated -10 to 1830°F (-23°C to 999°C) 1°F or °C
    Pressure/Draft Semiconductor ±0 to 80 inH2O 0.001 inH2O ±0.008 inH2O for ±0.16 inH2O ± 5% meas. val.
    Combustion Efficiency Calculated 0 to 100% 0.1%
    Excess Air Calculated 0 to 850% 1%
    BTU900-2 General Specifications
    Display Backlit graphic LCD display measuring 42 x 60 mm
    Internal data storage 300 positions with storage of three analyses each, including date, time and client’s name
    Communications port Bluetooth Communication
    USB with mini-USB connector
    IR interface for external printer using HP-IR protocol
    Power Supply Rechargeable battery, Li-Ion battery pack with internal protection circuit
    Battery life 12 hours of continuous operation
    Charging time 4 hours to recharge from 0% to 90%
    Operating Temperature 23 to 113°F (-5°C to +45°C)
    Storage Temperature -4 to 122°F (-20°C to +50°C)
    Operating humidity range 20% to 80% RH
    Air pressure Atmospheric
    Outer dimensions analyzer 8.6" x 3.9" x 2" (220 x 100 x 52 mm) W x H x D
    Weight 1.1 kg
    Each BTU-900-2 Combustion Analyzer Kit includes Oxygen (O2), Carbon Monoxide (CO), and Carbon Dioxide (CO2) sensor measurements and Efficiency, Draft, Differential Pressure manometer, Temperatures, Excess Air, 12" 10' Dual gas sampling probe and hose, IR Port that Prints to ANY HP-type IR printer, 600 Test Internal Memory, PC software package with USB cable, Li-Ion rechargeable batteries, AC charger, magnetic protective rubber holster, operating manual, calibration certificate and vinyl carrying case.
    close